Activity

From 08/01/2011 to 08/30/2011

08/30/2011

05:06 pm Revision 652: Only set CUL's FHTid if it's valid.
rdnzl
04:28 pm Revision 651: New version 0.1.200, you must upgrade your database!
Please make a backup first!
Added FHTid setting for CUL module.
Added more devicetypes to CUL interface db entry.
rdnzl
04:27 pm Revision 650: Tag for version 0.1.199 of DomotiGa.
rdnzl
02:42 pm Revision 649: CUL FHT parse changes.
rdnzl
01:48 pm Revision 648: Better CUL FHT decoding.
rdnzl
08:41 am Revision 647: Execute command action type gets contents parsed too.
Added parse template for device id|value.
Replace templates with their values in text inside event actions:
<%global ...
rdnzl

08/29/2011

09:49 pm Revision 646: Fixed FHT TFK decoding.
Display parsing errors in debug log.
Don't display CR in packet log output.
rdnzl
05:25 pm Revision 645: Changed devices log output.
Made FHT FTK sensors work in CUL module, needs testing. rdnzl
03:44 pm Revision 644: Completed decoding of CUL FS20 messages, needs testing.
rdnzl
02:29 pm Revision 643: Remove default rrd files from repos.
rdnzl
01:12 pm Revision 642: Query and display CUL version string in debug log upon init.
rdnzl
01:05 pm Revision 641: Display CUL FS20 Dim % instead of raw value.
Make CUL Cmdr Version button work. rdnzl

08/28/2011

08:59 pm Revision 640: Updated binaries.
rdnzl
08:58 pm Revision 639: Made EM1000-* devicetypes more generic.
rdnzl
08:40 pm Revision 638: Added CUL interface to sql upgrade and install script.
If your db is already at version 0.1.119 update it with:
mysql -u root -p domotiga <upgrade/01198to01199.sql
rdnzl
01:14 pm Revision 637: Changed default address.
rdnzl
01:05 pm New version 0.1.199 released
New version 0.1.199, you must upgrade your database!
Please make a backup first!
Added CUL module support, it's no...
rdnzl
01:02 pm Revision 636: New version 0.1.199, you must upgrade your database!
Please make a backup first!
Added CUL module support, it's not finished yet, FS20 and EM type msgs are correctly deco...
rdnzl

08/26/2011

12:46 pm Feature #3: Fix Fritz!Box module.
> Create callerid announcements per e-mail and popups.
Done.
rdnzl
08:14 am Disabled OpenID Login
I disabled OpenID login, while testing it all worked, but many users have problems with it. rdnzl

08/25/2011

08:22 am Site Moved
We ditched Trac and use Redmine now, placed server elsewhere, added more features, user comments, blog, forums, some ... rdnzl

08/24/2011

09:42 pm Revision 635: Changed contact e-mail address.
rdnzl

08/18/2011

02:35 pm Bug #69 (Closed): PLCBUS address conversion
rdnzl

08/17/2011

08:43 am Revision 634: Rewrote K8055 class, now using library calls, thanks Frank!
rdnzl

08/11/2011

01:28 pm Revision 633: Fixed sending empty list of batterystatus devices.
rdnzl

08/08/2011

11:11 am Revision 632: Fixed sql error 1136 in database dump file.
rdnzl

08/05/2011

10:42 pm Revision 631: Cleanup PLCBUS log output.
Display PLCBUS signal and noise strength report in log.
Removed unused lookup table entries.
rdnzl
06:52 pm Revision 630: Updated DomotiGaServer3 files too.
rdnzl
06:50 pm Revision 629: Updated the binaries.
rdnzl
05:07 pm Revision 628: Ask if user is sure that DomotiGa should be closed in server mode.
rdnzl
04:11 pm Revision 627: Some PLCBUS code cleanups.
Added DS18B20 sensor OWFS support for server too.
Major CTX35/TI203 code rewrite, it now features a command buffer.
rdnzl

08/04/2011

08:46 pm Revision 626: Fixed another bug in PLCBUS database device scan.
rdnzl
06:35 pm Revision 625: Fixed bugs in PLCBUS database device scan and address masks.
rdnzl
05:40 pm Revision 624: Allow housecode L through P and unitcode 12 through 16.
rdnzl

08/03/2011

09:46 pm Revision 623: Tag for version 0.1.198 of DomotiGa.
rdnzl
09:34 pm Revision 622: Updated DomotiGaServer3 code too.
rdnzl
08:25 pm Revision 621: Updated binaries to latest version.
rdnzl
08:23 pm Revision 620: New version 0.1.198, you must upgrade your database!
Please make a backup first!
Added PLCBUS setting for housecodes to poll.
Added timer delays to PLCBUS command queuing...
rdnzl

08/02/2011

02:45 pm Revision 619: Added command queue to PLCBUS code, and busy timer to wait after sending a command.
rdnzl
« Previous
Next »
 

Also available in: Atom