Activity
From 08/05/2011 to 09/03/2011
09/03/2011
-
09:36 pm Bug #73: FS20 switch status not changing
- tested and value1 sets to on but after the timer has run out the value stays on.
-
08:24 pm Revision 665: Fixed CUL FHT80 actuator parse code, please check.
-
07:40 pm Bug #73: FS20 switch status not changing
- Can you test r664, I have changed some things...
-
07:34 pm Revision 664: Display CUL FHTid also in decimal.
- If On-For-Timer received, set device value On. Vice versa for Off.
Implemented a temporary poll timer, to see if CUL ... -
05:41 pm Revision 663: Also update devicelist in client mode is autorefresh is off.
- Code cleanup in FDevices.
-
04:56 pm Revision 662: Display correct device status icons, also with light/dark.
-
01:45 pm Revision 661: Fixed tab order of heating and dvice editor, thank Jelle.
- Extra error catch when CUL interface is disconnected.
-
01:35 pm Bug #73: FS20 switch status not changing
- rdnzl wrote:
> Can you post the/a FS20 packet with this command? So I can test the changes to the code.
From the ... -
01:24 pm Bug #73 (In Progress): FS20 switch status not changing
- Can you post the/a FS20 packet with this command? So I can test the changes to the code.
09/02/2011
-
01:17 pm Bug #75 (Closed): Socket stays dead after Connection reset
- Due to a stofzuiger power outage my CUNO got disconnected and the socket died....
-
01:12 pm Bug #74 (Closed): FHT values wrong place
- !https://lh3.googleusercontent.com/-gb9sJtJ6RwU/TmC5VxmTzYI/AAAAAAAAANM/cXO1W_RYIho/Selection_003.png!
Value 1 sho... -
01:07 pm Bug #73 (Closed): FS20 switch status not changing
- When my motion sensor is triggered i see the following in the debug logging:...
09/01/2011
-
10:09 pm Bug #72 (Closed): Build Unknown/unsupported message format received
- What must we do with these msgs? Nothing, they are bogus, we don't ask for them and have no use for them, don't parse...
-
08:15 pm Bug #72 (Closed): Build Unknown/unsupported message format received
- After compiling the latest build i see NTP request messages?...
-
04:49 pm Revision 660: Device editor tab order changed, thanks Jelle.
- Switch of led for RFXComRX after init.
Updated binaries.
Don't display disabled log entries for disabled modules unle... -
01:32 pm Revision 659: Made CTX35 command buffer key more random.
- Control panel dim slider now has 16 steps.
Better syntax for example actions commands.
You can now use CUL Commander ... -
12:56 pm Revision 658: Allow a virtual device value to be set via event actions.
-
12:38 pm Revision 657: Make key of queue packet for PLCBUS more random.
- Added delay for PLCBUS H40 command.
-
10:54 am Bug #71 (Resolved): Error in weatherbug module?
- It's also described on the WeatherBug wiki page.
But it change the error to something more meaningful in r656.
-
10:21 am Revision 656: Added CUL basic FS20 device control for On/Off/Dim.
- Added CUL command queueing.
Fixed CUL FHT SyncTime message parse error.
Suppress logging empty CUL log lines.
Show on...
08/31/2011
-
11:47 pm Bug #71: Error in weatherbug module?
- Found the partial error between keyboard and chair. I noticed the "sample ID" is a1234567890 probably meaning the use...
-
11:41 pm Bug #71 (Closed): Error in weatherbug module?
- 2011/08/31 23:37:07 ERROR: XMLParser.ParseXML access denied to http://api.wxbug.net/getLocationsXML.aspx?ACode=A12345...
-
12:55 pm Revision 655: Also display decimal address for FHT devices.
-
09:03 am Revision 654: Cleaned up log output of FHT decoding.
- Display log entry if socket is closed by CUL device.
Formatted actuator value. -
08:21 am Revision 653: Fixed issue with CUL FS20 On value in wrong field.
08/30/2011
-
05:06 pm Revision 652: Only set CUL's FHTid if it's valid.
-
04:28 pm Revision 651: New version 0.1.200, you must upgrade your database!
- Please make a backup first!
Added FHTid setting for CUL module.
Added more devicetypes to CUL interface db entry. -
04:27 pm Revision 650: Tag for version 0.1.199 of DomotiGa.
-
02:42 pm Revision 649: CUL FHT parse changes.
-
01:48 pm Revision 648: Better CUL FHT decoding.
-
08:41 am Revision 647: Execute command action type gets contents parsed too.
- Added parse template for device id|value.
Replace templates with their values in text inside event actions:
<%global ...
08/29/2011
-
09:49 pm Revision 646: Fixed FHT TFK decoding.
- Display parsing errors in debug log.
Don't display CR in packet log output. -
05:25 pm Revision 645: Changed devices log output.
- Made FHT FTK sensors work in CUL module, needs testing.
-
03:44 pm Revision 644: Completed decoding of CUL FS20 messages, needs testing.
-
02:29 pm Revision 643: Remove default rrd files from repos.
-
01:12 pm Revision 642: Query and display CUL version string in debug log upon init.
-
01:05 pm Revision 641: Display CUL FS20 Dim % instead of raw value.
- Make CUL Cmdr Version button work.
08/28/2011
-
08:59 pm Revision 640: Updated binaries.
-
08:58 pm Revision 639: Made EM1000-* devicetypes more generic.
-
08:40 pm Revision 638: Added CUL interface to sql upgrade and install script.
- If your db is already at version 0.1.119 update it with:
mysql -u root -p domotiga <upgrade/01198to01199.sql -
01:14 pm Revision 637: Changed default address.
-
01:05 pm New version 0.1.199 released
- New version 0.1.199, you must upgrade your database!
Please make a backup first!
Added CUL module support, it's no... -
01:02 pm Revision 636: New version 0.1.199, you must upgrade your database!
- Please make a backup first!
Added CUL module support, it's not finished yet, FS20 and EM type msgs are correctly deco...
08/26/2011
-
12:46 pm Feature #3: Fix Fritz!Box module.
- > Create callerid announcements per e-mail and popups.
Done. -
08:14 am Disabled OpenID Login
- I disabled OpenID login, while testing it all worked, but many users have problems with it.
08/25/2011
-
08:22 am Site Moved
- We ditched Trac and use Redmine now, placed server elsewhere, added more features, user comments, blog, forums, some ...
08/24/2011
08/18/2011
08/17/2011
08/11/2011
08/08/2011
08/05/2011
-
10:42 pm Revision 631: Cleanup PLCBUS log output.
- Display PLCBUS signal and noise strength report in log.
Removed unused lookup table entries. -
06:52 pm Revision 630: Updated DomotiGaServer3 files too.
-
06:50 pm Revision 629: Updated the binaries.
-
05:07 pm Revision 628: Ask if user is sure that DomotiGa should be closed in server mode.
-
04:11 pm Revision 627: Some PLCBUS code cleanups.
- Added DS18B20 sensor OWFS support for server too.
Major CTX35/TI203 code rewrite, it now features a command buffer.
Also available in: Atom