Activity
From 10/15/2011 to 11/13/2011
11/13/2011
-
08:16 pm Revision 736: Added missing iPhone client files.
-
06:59 pm Revision 735: Renamed directory.
-
06:41 pm Revision 734: Added simple Android client, coded by Reno, thanks!
-
04:58 pm Revision 733: Added icons for iPhone client.
-
12:28 pm Revision 732: Added support for DS2438, DS2406, DS2414, DS2450 devices to OWFS code.
- Thanks David!
11/12/2011
-
08:03 pm Revision 731: Updated binaries to latest revision.
-
07:57 pm Revision 730: Fixed EIB/KNX EIS5 packet parsing, so receiving temperatures should work now.
-
07:19 pm Revision 729: Removed spaces from empty edit graphs combobox entries.
- Rearranged edit graph group lists.
-
06:50 pm Revision 728: Don't display duplicate event categories.
- Refresh used event categories upon page refresh.
-
05:37 pm Revision 727: Fixed xmlrpc devicelist method for lastseen info.
- Added iPhone webclient created by Mike, thanks!
Added a control view to the standard webclient for switching devices,... -
05:01 pm Revision 726: Fixed tab focus order for Bwired settings.
- Display info about URL format.
-
04:46 pm Revision 725: Added code from deletion of globalvars when running client/server.
-
04:43 pm Revision 724: Also display Shell return value errors without debug enabled.
-
04:42 pm Revision 723: Ignore non float values as HDD temperature.
-
04:41 pm Revision 722: Better XML parse error catching.
- Better set themorstat globalvar call.
-
04:38 pm Revision 721: Better Time event code.
-
04:37 pm Revision 720: Better auto device creation, also lastseen and location are set to default.
- Also added lastseen field to event macro's like <#device name|lastseen#>
-
04:34 pm Revision 719: Disabled DNS resolve for better stability for now, so you need to specify ip addres...
-
04:32 pm Revision 718: Added xmlrpc method for globalvars, version is 0.10 now.
-
04:27 pm Revision 717: Small UPS string parse changes.
-
04:26 pm Revision 716: Fixed X10 addresses for RFXCom xPL interface.
- Fixed Temp08 module name in SerialPort list.
11/05/2011
-
10:41 am Revision 715: Close HDDTemp socket at program close.
- Rearranged sunset/rise code.
-
10:34 am Revision 714: Display device id's larger than 99.
-
10:32 am Revision 713: Only check for duplicate addresses against enabled devices.
11/04/2011
11/02/2011
-
07:51 pm Revision 711: Report correct signal strenght for CUL packets.
- Also display received values of S300TH in debug mode.
-
01:25 pm Revision 710: Correctly parse CUL FHT warning packets.
-
12:39 pm Revision 709: Create correct RRDTool update command if value is empty or a string.
-
12:36 pm Revision 708: Return correct calibrated value.
-
12:35 pm Revision 707: Convert incoming RFXComxPL X10 addresses to the correct format.
-
12:33 pm Revision 706: Ignore CUL FHT hightemp packet if no lowtemp packet is received first.
-
08:23 am Revision 705: Removed references to bCULAutoCreate variable.
10/29/2011
-
11:21 am Revision 704: Code cleanups.
- Fix bug in icon display on climate page for certain devices, thanks Luca!
-
11:17 am Revision 703: Don't auto create a device if it's type is unknown.
-
11:15 am Revision 702: Added description field to UV1/UV2 xPL decoding.
-
11:01 am Revision 701: Commit correct DomotiGaServer CUL code.
- Code cleanup, formatted rain sensor value.
-
10:59 am Revision 700: Removed CUL poll timer.
- Removed CUL autocreate code, done now for all devices.
10/27/2011
10/26/2011
10/25/2011
-
09:30 pm Revision 697: Updated binaries.
-
09:17 pm Revision 696: Fixed missing RFXComTX AC call, and remove optional function calls.
-
05:39 pm Revision 695: Updated binary.
-
05:38 pm Revision 694: Fix floorplan error on auto created devices.
-
05:16 pm Revision 693: New version 0.1.201, you must upgrade your database!
- Backups of devices and devicetype tables are stored in /tmp too.
Renamed OneWire module to Temp08.
Added xPL module t...
10/17/2011
-
01:40 pm Revision 692: Added simple device switch functionality to webclient, thanks Wouter!
- Needs some more work.
-
01:32 pm Revision 691: Tag for version 0.1.200 of DomotiGa.
-
11:08 am Revision 690: Fixed typo.
-
11:07 am Revision 689: Code cleanup.
-
11:06 am Revision 688: Code cleanup.
-
11:04 am Revision 687: Code cleanup.
-
11:02 am Revision 686: When saving RRD graphs, check if RRDTool is enabled, warn if not.
-
10:45 am Revision 685: You can now use */ in cron event trigger fields, eg. */10 * * * * means run every 1...
- Also ranges together with / in same field are implemented, eg. 5-30/5 is every 5 mins between 5-30.
Fixed bug in rang... -
10:16 am Revision 684: Cleanup Relay Socket connect log output.
-
10:15 am Revision 683: Cleanup log output.
-
09:36 am Revision 682: Store FHT80 thermostat values in different device value fields.
- Calculate correct FHT measured temperatures from high and low byte.
Fixed FHT SyncTime value. -
09:24 am Revision 681: Disabled async DNS queries, at least they work now.
-
09:23 am Revision 680: Fixed bug in K8055 settings form.
-
09:21 am Revision 679: Added host param to admin database backup code, so it works in client/server mode too.
-
09:03 am Revision 678: Fixed 'Error while running CheckTimeNowEvents query!' error when no triggers are de...
Also available in: Atom