Activity
From 11/29/2011 to 12/28/2011
12/28/2011
-
03:12 pm Bug #59 (Closed): Globalvars in client are all strings instead of bool, integers etc.
-
03:12 pm Bug #55 (Closed): Cannot set housemode or audiomute from client GUI
-
03:12 pm Feature #3 (Closed): Fix Fritz!Box module.
-
03:11 pm Bug #60 (Closed): Implement reconnect timer/code to TCP socket routines.
-
03:11 pm Feature #66 (Closed): Change sliders to buttons with +/- areas if possible
-
03:10 pm Bug #81 (Closed): S300TH addressing not correctly decoded
-
03:09 pm Bug #84: enabled warning on ignored devices
- Will be fixed in next version.
-
03:04 pm Feature #85 (Closed): Add 1 sec Timer for FS20TK device (doorbel)
12/27/2011
-
05:07 pm Revision 779: Tag for version 0.1.201 of DomotiGa.
-
05:05 pm Revision 778: Revert tag of 0.1.199
-
04:44 pm Revision 777: Tag for version 0.1.199 of DomotiGa.
12/08/2011
-
06:24 pm Feature #85: Add 1 sec Timer for FS20TK device (doorbel)
- Approved ;-)
-
05:53 pm Feature #85: Add 1 sec Timer for FS20TK device (doorbel)
- I have added that functionality to r776, please test.
-
05:52 pm Revision 776: Only send data to CUL interfaces when connected/active.
- When setting a FS20 DoorBell to On from DomotiGa set it to Off again after a second.
-
05:27 pm Feature #85: Add 1 sec Timer for FS20TK device (doorbel)
- KidE wrote:
> i have to refrase myself:
>
> If i switch the device on from within domotiga the timer is not triggere... -
05:16 pm Feature #85: Add 1 sec Timer for FS20TK device (doorbel)
- i have to refrase myself:
If i switch the device on from within domotiga the timer is not triggered.... -
05:10 pm Feature #85: Add 1 sec Timer for FS20TK device (doorbel)
- ...
-
04:37 pm Feature #85 (Resolved): Add 1 sec Timer for FS20TK device (doorbel)
- Implemented in r775.
If FS20 device of type description "Bell Button" generates an On value, it will go to Off after... -
04:36 pm Revision 775: Code cleanup.
- Toggle FS20 Bell Button device to Off after 1 second On.
-
04:11 pm Revision 774: Same.
-
04:11 pm Revision 773: Added SetGlobalVar action to Condition editor.
-
04:10 pm Revision 772: If Event action timer is already running for a certain event, don't stop but restar...
-
04:09 pm Revision 771: Code cleanup.
12/06/2011
-
07:50 pm Revision 770: Fixed problems with House and Audio mode.
-
07:33 pm Revision 769: Fixed bug regarding initializing CUL interface.
-
05:23 pm Bug #73 (Closed): FS20 switch status not changing
-
10:01 am Revision 768: Removed GUI calls from XMLRPC and event code.
-
09:57 am Revision 767: Remove client code.
-
09:57 am Revision 766: Removed GUI calls from XMLRPC and GUI code.
12/05/2011
-
03:18 pm Revision 765: Update Main window statusbar information after every globalvar update.
-
02:51 pm Revision 764: Added a GlobalVar editor.
- Added Francois's thermostat code.
This thermostat is event driven, wiki will be updated with howto. -
11:14 am Revision 763: Really fix Digitemp error management temperature.
- Made FirstByte variable public.
-
11:11 am Revision 762: Really
12/04/2011
-
10:18 pm Revision 761: Made FloorPlan Editor window resizable, so bigger pictures can be used.
-
07:18 pm Revision 760: Update globalvars in client mode too, via XMLRPC method.
- Made thermostat compares case insensitive.
Added code to delete globalvar. -
07:11 pm Revision 759: Added Enabled column to Events list.
-
07:11 pm Revision 758: Made condition checks less case sensitive.
- Refresh status panel after globalvars updates.
-
07:09 pm Revision 757: Added XMLRPC methods for thermostat control, API has version 0.11 now.
11/30/2011
-
01:12 pm Feature #85 (Closed): Add 1 sec Timer for FS20TK device (doorbel)
- Ron,
Could you please add a 1 second timer to the FS20TK device so that the status switches back to off after 1 se...
11/29/2011
-
10:03 pm Bug #73: FS20 switch status not changing
Yes.... my request has been granted ;-) it works and is verified! (only Jelle has a unresolved issue)...-
04:30 pm Revision 756: Fixed bug in parsing group addresses.
- Fixed some RFXComTX AC Cmdr issues.
-
03:57 pm Revision 755: Fixed error in LEDMatrix display from event actions, thanks David!
-
03:55 pm Revision 754: Added On/Off-For-Timer support for CUL FS20 devices so device status keeps uptodate.
- Fixed bugs in event action timer delays.
Fixed bug in calculation of CUL FS20 On/Off-For-Timer duration. -
02:59 pm Feature #80: Add rulers to the floorplan editor
- KidE wrote:
> Sorry, i thought is was that obvious :P
>
> I have 3 floorplans of 800x600 and when you drop a dev... -
02:42 pm Bug #73: FS20 switch status not changing
- Ok..I just implemented *-For-Timer support on my dev box ;)...
-
11:42 am Feature #80: Add rulers to the floorplan editor
- Sorry, i thought is was that obvious :P
I have 3 floorplans of 800x600 and when you drop a device onto it in the ... -
11:30 am Revision 753: Fixed bug in optional params.
-
11:10 am Feature #80: Add rulers to the floorplan editor
- KidE wrote:
> This doesn't need further explanation i think ;-)
You mean like rulers for measurement? Why?
-
11:09 am Bug #82: Weatherbug crashes when click "view" button
- KidE wrote:
> I Think ron made a typo of some kind
>
> in the FWeather
>
> line
> IF Left(StrLine, 48) = "aws... -
09:47 am Revision 752: Changed error message.
Also available in: Atom